| | | | | | Product
PerformanceTests and inspection of test data have been carried out to
determine the properties and performance of the Eurobrick Insulated Brick Cladding
System for:- -
wind loading -
durability
-
adhesion between layers -
performance
in relation to fire resistance to water penetration and water vapour -
transmission -
resistance to
impact -
resistance to cyclic freezing and thawing
-
resistance to thermal and moisture cycling
Some of the results are outlined in Table 1. | |
TABLE 1 : Properties
of the system | | Property | Result |
| Surface spread of flame | Class 1 |
| BS 476: Part 7: 1971 | |
| Fire performance | Class
0 | | Building Regulations Classification | |
| Water vapour resistance | 130 MNs/g |
Impact Resistance - Hard Body | 7.5
J - no damage affecting safety | | Thermal Conductivity
of Insulation | 0.026 W/mK | | Adhesion
between layers | min 0.6 N/mm2 | | Weight
of system | nominal 29kg/m2 | | | | | | |